Subj.758 Section 4 Page 4389 Issued:1989-01-20
Revised:2011-09-27
Style 4389 Multiple-conductor cable using non-integral jacket
Rating 150 deg C, 200 deg C, 600 Vac, Horizontal Flame, Cable Flame.
Insulated Conductor Labeled or complying with manufacturer’s AWM procedure.
Assembly 2-61 conductors, twisted together. Length of lay is not specified. Barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering Optional – A 6 mil, or heavier Silicone Rubber covering.
Shield Optional.
Jacket Extruded SR.
Number of insulated conductors Minimum average thickness Minimum thickness at any point
2-7 45 mils 36 mils
8-16 60 mils 48 mils
17-25 94 mils 76 mils
26-61 125 mils 100 mils
Standard Appliance Wiring Material UL 758.
Marking General.
Use External interconnection of high temperature cooking appliances. Where not subject to mechanical abuse and where the acceptability of the combination is to be determined by UL.